Specification Brand : SHIHUANI BulletPoint1 : 1. Digital Multimeter:This power energy meter can measure and display voltage current active power energy frequency and power factor at the same time.with split current transformer,more convenient to install . BulletPoint2 : 2. Overload Alarm function:Backlight and power will flash simultaneously to give an alarm when exceeding the preset value.You can preset power limit by yourself. BulletPoint3 : 3. Automatic Data Storage Function:The last test data is stored automatically when the power supply abruptly lose. Don't worry about data loss due to sudden power outages. BulletPoint4 : 4. One-touch Control:The button can be used to control the backlight,reset energy, preset power alarm limit. BulletPoint5 : 5. HD Display:HD display, 180° viewing without dead angle, with backlight function, this power meter is clearly visible whatever day or night. Color : 3CT 1000A ExternallyAssignedProductIdentifier : 3041255617442 ItemName : EM-06 Digital Multimeter, Three Phase Volt(L-L),(L-N), Ampere,Frequency, Phase Sequence Display Panel Meter 12 in 1(3CT 1000A) ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : current-clamps Manufacturer : SHIHUANI ModelName : SHIHUANI ModelNumber : SHIHUANI NumberOfItems : 1 PartNumber : SHIHUANI ProductDescription : General EM-06 Multimeter are designed to display 3 phase current, voltage and frequency. Usage and Working Principle Make the connections according to the diagram. Connect the current transformers before electric charges to be connected to the system. Current transformers dont sense voltages which connected before them. Apply max 5 A the current inputs. Press the menu button once the energy given to the device.Please enter the current value that you are using by pressing up down buttons, to save it please press menu button once again. If the current transformer value is over 1000/5 please be sure that you can see the kA leds. Under normal working circumstances when the current value is over 1000A KA led that belongs to that phase gets on. You can observe the current values at the sytstem trough the second display group at the right side of the screen. You can see the frequency between phase and phase, phase and neutral at the first display group. When the voltage values is shown (V) led gets on. While pressing the up button ,phase-phase range can be seen.When the phase-phase values is shown you can see the leds on phase phase. While pressing theup buttons you can see the frequency value and Hz led gets on. Phase Sequence: If the phase sequence is reverse you can see the (X) led gets on which take place in the 1st display group. Maintenance Switch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaning. Warnings Please use the device according to the manual. Don't use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device. Specifications Operating Voltage(Un).......: 85V - 240V AC Operating Fre ProductSiteLaunchDate : 2025-04-03T07:49:11.990Z Size : One Size UnitCount : 1 UnspscCode : 41113600