Specification AgeRangeDescription : adult BatteriesIncluded : 1 BatteriesRequired : 1 Brand : SHIHUANI BulletPoint1 : 1. Digital Multimeter:This power energy meter can measure and display voltage current active power energy frequency and power factor at the same time.with split current transformer,more convenient to install . BulletPoint2 : 2. Overload Alarm function:Backlight and power will flash simultaneously to give an alarm when exceeding the preset value.You can preset power limit by yourself. BulletPoint3 : 3. Automatic Data Storage Function:The last test data is stored automatically when the power supply abruptly lose. Don't worry about data loss due to sudden power outages. BulletPoint4 : 4. One-touch Control:The button can be used to control the backlight,reset energy, preset power alarm limit. BulletPoint5 : 5. HD Display:HD display, 180° viewing without dead angle, with backlight function, this power meter is clearly visible whatever day or night. BulletPoint6 : 【Extra OPM for you】- High Precision Optial Power Meter KPM-35-G-A: Support 7 Wavelengths - 850/980/1300/1310/1490/1550/1625nm; Measurement Range -70~+6dBm; 2.5mm Universal Interface +SC; Support Self-calibration. Color : AC500V Department : unisex-adult ExternallyAssignedProductIdentifier : 3041255616476 ExternallyAssignedProductIdentifier1 : 635401835588 ExternallyAssignedProductIdentifier2 : 0635401835588 Hazmat1 : LITHIUM ION BATTERIES PACKED WITH EQUIPMENT Hazmat10 : CN_SmallLithiumIonBatteryWithEquipment Hazmat11 : DE_SmallLithiumIonBatteryWithEquipment Hazmat12 : EG_SmallLithiumIonBatteryWithEquipment Hazmat13 : ES_SmallLithiumIonBatteryWithEquipment Hazmat14 : FR_SmallLithiumIonBatteryWithEquipment Hazmat15 : GB_SmallLithiumIonBatteryWithEquipment Hazmat16 : IE_SmallLithiumIonBatteryWithEquipment Hazmat17 : IN_SmallLithiumIonBatteryWithEquipment Hazmat18 : IT_SmallLithiumIonBatteryWithEquipment Hazmat19 : JP_SmallLithiumIonBatteryWithEquipment Hazmat2 : UN3481 Hazmat20 : MX_SmallLithiumIonBatteryWithEquipment Hazmat21 : NL_SmallLithiumIonBatteryWithEquipment Hazmat22 : PL_SmallLithiumIonBatteryWithEquipment Hazmat23 : SA_SmallLithiumIonBatteryWithEquipment Hazmat24 : SE_SmallLithiumIonBatteryWithEquipment Hazmat25 : SG_SmallLithiumIonBatteryWithEquipment Hazmat26 : TR_SmallLithiumIonBatteryWithEquipment Hazmat27 : US_SmallLithiumIonBatteryWithEquipment Hazmat28 : ZA_SmallLithiumIonBatteryWithEquipment Hazmat3 : II Hazmat4 : 9 Hazmat5 : AE_SmallLithiumIonBatteryWithEquipment Hazmat6 : AU_SmallLithiumIonBatteryWithEquipment Hazmat7 : BE_SmallLithiumIonBatteryWithEquipment Hazmat8 : BR_SmallLithiumIonBatteryWithEquipment Hazmat9 : CA_SmallLithiumIonBatteryWithEquipment IncludedComponents : FX39 main chip board ItemName : SDM-V96T 3 * 380V+Neutral Digital Three Phase Voltmeter, Shows Phase Sequence, Slim Compact, Panel Meter ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : current-clamps Manufacturer : SHIHUANI MeasurementAccuracy : 0.01dB MeasurementType : Decibels (dB) ModelName : SHIHUANI ModelNumber : SHIHUANI NumberOfBoxes : 1 NumberOfItems : 1 NumberOfLithiumIonCells : 4 PartNumber : SHIHUANI PowerSourceType : Battery Powered ProductDescription : General Designed to monitorize voltage between phase-neutral and phase-phase. The device also shows phase sequence. Usage and Working Principle Make the connections according to the diagram. When the device is energized, the display shows the voltage values at inputs L1 ,L2 andL3. When there is voltage values belonging to phases L1, l2 and L3 on the screen. When the SELECT button is pressed, the device displays the L12, L23, L31 phase-to-phase voltage values on the screen. When SELECT button is pressed again, the device will show the phase sequence. If the phase sequence is correct, LI, L2, L3 will be written from top to bottom in the display. If the phase sequence is reversed, L1, L3, L2 will be written from top to bottom in the display. Maintenance Switch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaning. Warnings Please use the device according to the manual. Don't use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can reach easily. Mark the switch and circuit breaker as releasing connection for device. Specifications Operating Voltage(Un)....: 140V - 270V AC Operating Frequency.......: 50/60 Hz. <;4VA Operating Temperature..: -20°C.....+55°C Meas.Range(L-N)...........: 5-300V AC(L1 must be least 140V) Meas.Range(L-L)............:5-500V AC Measurement Precision..: ±%1 Display..............................: 3*3 digit 14mm display Connection Type..............: Plug-in terminal Cable Diameter.................: 1,5mm² Weight................................: Max. 300gr. Panel Hole Sizes................: 91x91mm Mounting...........................: Panel front mounted <;2000meter Dimensions Connection diagram ProductSiteLaunchDate : 2025-04-03T07:48:48.402Z Size : 96*96MM_220-240V SpecificationMet1 : CE SpecificationMet2 : RoHS Style : Morden Art SupplierDeclaredDgHzRegulation : transportation UnitCount : 1 UnspscCode : 31162900 UpperTemperatureRating : 50 degrees_celsius