Specification Brand : Gearwell BulletPoint1 : [High Accuracy] S IGNAL generator is small and bright, the button character operation interface is easy to use, has a long standby time and high accuracy. BulletPoint2 : [DC Voltage Measurement And Output] With 100 MV, 30V DC voltage measurement and output, 20 mA DC current measurement and switching value measurement, output and analog output. BulletPoint3 : [Multifunctional] V, MA manual step output, automatic waveform output, and display V, MA and percentage at the same time. Eight proportional divisions (R, S, B, K, E, J, T and N) thermocouple measurement and output function. BulletPoint4 : [Cycle Detection Function] Function S IGNAL generator can display Celsius and Fahrenheit, with automatic and manual cold junction compensation function, cycle detection function, can provide 24V loop power and measure current at the same time. BulletPoint5 : [Widely Application] The S IGNAL generator is mainly used to debug the industrial field PLC, process instrumentation, electric valve, etc. Color : GV24L MK2 220V ExternallyAssignedProductIdentifier : 9162354015213 ItemName : 71B S IGNAL Generator Portable High Accuracy Function Generator S IGNAL Process Calibrator S IGNAL Generator High Accuracy Function Generator ItemPackageDimensions_Height : 7 centimeters ItemPackageDimensions_Length : 21 centimeters ItemPackageDimensions_Width : 16 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : function-generators Manufacturer : Gearwell Material : ABS ModelName : Gearwell9uyrv8h6fm ModelNumber : Gearwell9uyrv8h6fm NumberOfItems : 1 PartNumber : Gearwell9uyrv8h6fm ProductDescription : Item Type: S IGNAL Generator Product Model: RuoShui 71B Material: Plastic Capacitive Load: 0.01uF Display Refresh: 2-3 times/sec Overload P ROTECTION: 50mA / 30V Working Temperature And Humidity: 0-40℃ and humidity below 85% (no condensation) Storage Temperature And Humidity: -20℃-60℃ and humidity lower than 90% (no condensation) Ideal Working Environment: 23±5℃ and humidity lower than 75% (no condensation) Temperature Coefficient: 0.1 x basic accuracy/℃ (temperature 28℃) Environmental Conditions For Use: Indoor/outdoor use (not waterproof), 0-2000m above sea level Out Of Range Display: OL Battery: 3 x AAA battery (Battery Not Included) Low Battery Warning: Support Automatic Power Off: Support Warm Up Time: 10Min Calibration: External calibration Calibration Period: 1 year
Measurement Function Range Measuring Range Resolution Accuracy DC Voltage 100mV -10.0mV~110.0mV 100uV 0.2%+4 30V -5.00V~30.00V 10mV 0.2%+4 DC Current 20mA 0.00mA~22.00mA 0.01mA 0.2%+4 Thermocouple R 0℃~1760℃ 1℃ 0.2%+4 S 0℃~1760℃ B 400℃~1820℃ K -200℃~1370℃ E -200℃~1000℃ J -200℃~1200℃ T -200℃~400℃ N -200℃~1300℃ Output Function Range Measuring Range Resolution Accuracy
DC Voltage 100mV 0.0mV~110.0mV 100uV 0.2%+4 10V 0.00V~11.00V 10mV 0.2%+4 DC Current 20mA 0.00mA~22.00mA 0.01mA 0.2%+4 Analog Transmitter Simulation -20mA 0.00mA~-22.00mA 0.01mA 0.2%+4 Loop Power Loop 24V ±10% Thermocouple R 0℃~1760℃ 1℃ 0.2%+4 S 0℃~1760℃ B 400℃~1800℃ K 0℃~1350℃ E 0℃~700℃ J 0℃~950℃ T 0℃~400℃ N 0℃~1300℃
Package List: 1 x S IGNAL Generator (Battery Not Included) 2 x Test Line 2 x Connector 1 x Storage Bag 1 x Manual
Note: Please read the instructions ProductSiteLaunchDate : 2024-09-20T19:20:48.083Z Size : One Size UnitCount : 1 UnspscCode : 31160000