Specification Brand : LJIA BulletPoint1 : Double Clamp Grounding Resistance Tester is specially design for the measurement of earth resistance, soil resistivity, earth voltage, leakage current of grounding line, AC current, DC resistance. BulletPoint2 : Adopting the latest digital technology, precise 4-pole, 3-pole and simple 2-pole method, selection method, double clamp method to measure grounding resistance, for earth resistance measurement; large caliber clamp design, can use to measure the grounding system which adopt large-scale down conductor. BulletPoint3 : can flexibly and precisely measure the value of grounding resistance in every complicated situation like single point grounding, grounding mesh; it is not need to disconnect any parallel connection pole when measuring parallel-grounding, and massively improve the convenience when measuring. BulletPoint4 : Double Clamp Grounding Resistance Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. BulletPoint5 : At the same time it can store 2000 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, and alarm indicator, auto-shut down and with the functions like historical data access, reading, preservation, report forms, printing and so on. Color : One Color ExternallyAssignedProductIdentifier : 9454352904041 Hazmat1 : LITHIUM ION BATTERIES PACKED WITH EQUIPMENT Hazmat10 : CA_SmallLithiumIonBatteryWithEquipment Hazmat11 : CN_SmallLithiumIonBatteryWithEquipment Hazmat12 : IT_SmallLithiumIonBatteryWithEquipment Hazmat13 : ES_SmallLithiumIonBatteryWithEquipment Hazmat14 : IN_SmallLithiumIonBatteryWithEquipment Hazmat15 : MX_SmallLithiumIonBatteryWithEquipment Hazmat16 : SG_SmallLithiumIonBatteryWithEquipment Hazmat17 : AU_SmallLithiumIonBatteryWithEquipment Hazmat18 : BR_SmallLithiumIonBatteryWithEquipment Hazmat19 : TR_SmallLithiumIonBatteryWithEquipment Hazmat2 : UN3481 Hazmat20 : AE_SmallLithiumIonBatteryWithEquipment Hazmat21 : SA_SmallLithiumIonBatteryWithEquipment Hazmat22 : EG_SmallLithiumIonBatteryWithEquipment Hazmat23 : NL_SmallLithiumIonBatteryWithEquipment Hazmat24 : SE_SmallLithiumIonBatteryWithEquipment Hazmat25 : PL_SmallLithiumIonBatteryWithEquipment Hazmat26 : BE_SmallLithiumIonBatteryWithEquipment Hazmat27 : ZA_SmallLithiumIonBatteryWithEquipment Hazmat28 : IE_SmallLithiumIonBatteryWithEquipment Hazmat3 : II Hazmat4 : 9 Hazmat5 : US_SmallLithiumIonBatteryWithEquipment Hazmat6 : GB_SmallLithiumIonBatteryWithEquipment Hazmat7 : DE_SmallLithiumIonBatteryWithEquipment Hazmat8 : FR_SmallLithiumIonBatteryWithEquipment Hazmat9 : JP_SmallLithiumIonBatteryWithEquipment ItemName : Ground Tester, Double Clamp Grounding Resistance Tester Of Earth Resistance Measurement Soil Resistivity Meter Leakage Current Tester ETCR3200,Safer and Faster ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : ground-resistance-meters Manufacturer : LJIA Material : plastic ModelName : ETCR3200 ModelNumber : ETCR3200 NumberOfItems : 1 PartNumber : ETCR3200 ProductDescription : Function:4-pole, 3-pole and simple 2-pole, selection, double clamp method measure grounding resistance, soil resistivity; Measurement of earth voltage, AC voltage, leakage current of AC current Power Supply:DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours ) Caliber of clamp:Φ68mm Measurement Range: Selection method: 0.00Ω-3000Ω; Double clamp method: 0.00Ω-9000kΩ; 2/3/4 pole method:0.00Ω~30.00kΩ; Soil resistivity:0.00Ω~9000kΩ; DC resistance:0.00Ω~30.00kΩ; Earth voltage:0.0V~100.0V; AC current:0.00mA~600A Measuring Mode:Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance Test Frequency: 128Hz/111Hz/105Hz/94Hz(AFC). Short-circuit Test Current:AC 20mA max Open-circuit Test Current: AC 40V max Test Voltage Wave:Sine wave Electrode Distance Range:Can be set 1m-100m Backlight:Blue screen backlight, suitable for dim places Standard Test Wire:4 wires: each for red 20m, black 20m, yellow 10m, and green 10m Simple Test Wire:2 wires: each for red 1.6m and black 1.6m Measuring Rate:Voltage to ground: about 2 times/second; Current to ground: about 2 times/second; Earth resistance, soil resistivity: about 5 seconds/time Measuring Times:Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) RS232 Interface: One piece of RS232 communication wire, with length 1.5m,RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed. Power Consumption:Standby: about 20mA (Backlight shut off); Boot and with backlight: about 45mA (25mA without backlight); Measurement: about 100mA (Backlight shut off) Accessories:Tester: 1PC;clamp:2PC; Earthing Rod: 2PCS; Testing Wire: 3PCS; Simple testing wire: 2PCS; RS232 Com-cable: 1PC; Software disk: 1PC; Tester bag: 1PC ProductSiteLaunchDate : 2025-03-25T03:42:05.336Z Size : One Size UnitCount : 1 UnspscCode : 41113600