Specification Brand : YDuupxe BulletPoint : AZ7798 CO2 Temperature RH Data Logger Measure the Indoor Air Quality Value BulletPoint1 : Short Response Time: The gas sensor module has a short response time, which enables it to detect gas concentration quickly and stably and grasp the gas content of the environment. BulletPoint2 : Double Panel Design: The gas sensor module adopts double panel design with power indicator and TTL output indicator. BulletPoint3 : DO Switching : O3 gas sensor module with DO switching (TTL) output and AO analog output, analog output voltage changes with concentration TTL output high and low levels. BulletPoint4 : High Sensitivity: gas sensor module with high sensitivity and accuracy can effectively detect in air without external calibration and can be calibrated automatically. BulletPoint5 : Simple Structure: The gas sensor module has a simple structure and can be used in a variety of environments with a wide range of applications to meet the needs of a variety of applications and a good use experience. Color : White IncludedComponents : NO ItemName : Gas Detection Sensor Module High Sensitivity Gas Sensor Module Dual Panel TTL Output for Environment Monitoring ItemPackageDimensions_Height : 2 centimeters ItemPackageDimensions_Length : 6 centimeters ItemPackageDimensions_Width : 4 centimeters ItemTypeKeyword : indoor-air-quality-meters Manufacturer : YDuupxe Material : Plastic + Electronic Components ModelNumber : YDuupxemw26d7ygaf NumberOfItems : 1 PartNumber : YDuupxemw26d7ygaf PowerSourceType : Battery Powered ProductDescription : Specification: Item Type: Gas Sensor Module Material: PCB, ABS Power Consumption (Current): 150mA DO Output: TTL digital 0 and 1 (0.1V and 5V) AO Output: Analog levels Operating Temperature: -10 - 50℃ (Nominal Temperature ℃) Humidity: 95% RH (Nominal humidity 65% RH)
How to Use: Wiring Method: 1. VCC: Connect to the positive side of the power supply (5V) 2. GND: Connected to the negative side of the power supply 3. DO: TTL switch output 4. AO: Analog output
PackageList: 1 x Gas Sensor Module
Note: 1. After the sensor is powered on, it needs to warm up about 20S, the measured data is stable, the sensor heating is normal, because the internal electric heating wire, if it is hot, it is not normal. 2. Long term exposure to harsh environments. Whether the sensor is energized or not, if exposed to high humidity, high temperature, high pollution and other adverse environments for a long time, will seriously affect the performance of the sensor. ProductSiteLaunchDate : 2024-07-30T17:18:00.664Z Style : artdeci SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnitCount : 1