Micrometer Hole Hole Inner Diameter Gauge 5-30mm Range 0.01mm Accuracy Bore Micrometer Micrometer

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 6800/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
AgeRangeDescription : adult
Brand : WBTY
BulletPoint1 : With the locking device, the machine structure is more intuitive and convenient to read
BulletPoint2 : High-quality alloy measurement. High-quality alloy measurement, which can be used for various internal size measurements, fine workmanship and no burrs. luthier tools
BulletPoint3 : High-quality alloy measurement for various internal size measurements, fine workmanship.
BulletPoint4 : Clear for marking line for
BulletPoint5 : With the locking device, the machine structure is more intuitive and convenient to read.
Color : 50-100mm
ExternallyAssignedProductIdentifier : 7637895052390
ItemName : Micrometer Hole Hole Inner Diameter Gauge 5-30mm Range 0.01mm Accuracy Bore Micrometer Micrometer
ItemPackageDimensions_Height : 4 centimeters
ItemPackageDimensions_Length : 17 centimeters
ItemPackageDimensions_Width : 9 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : inside-micrometers
Manufacturer : WBTY
Material : Metal
ModelName : DONGSE
ModelNumber : WBTY6o9mhqpc0g
NumberOfBoxes : 1
NumberOfItems : 1
PartNumber : WBTY6o9mhqpc0g
ProductDescription : Technical data:
Type: Internal Micrometer
Measuring range: 5 mm ~ 30 mm.
Material: stainless steel.
: 0.01 mm.
Weight: approx. 268g
Zero settings:
Clean the surface of the measuring anvil heads with a soft cloth and then turn the gauge to bring two measuring surfaces in. If the two zero lines of the differential sleeve and the fixed barrel do not match, use the following two methods to adjust.
Method I:If the error is less than 0.02mm (0.001), use the ratchet stop to tighten the screw, and then use the wrench to tighten the fixed barrel until two zero lines are aligned.
Method II, if the error is greater than 0.02 mm (0.001),
Step 1: Use the ratchet stop to tighten the screw, then loosen the ratchet stop with a wrench and remove the differential sleeve.
Step 2: Re-align the zero lines of the fixed barrel and differential sleeve, and then put the ratchet stop back in. Adjust it again with Method I if necessary.
Note: Under normal use, the micrometer does not need to be calibrated. Micrometers only need to be calibrated when they are severely worn.
Package includes:
1 x internal micrometer.
1 x wrench.
1 x calibration ring.
1 x packaging box
ProductSiteLaunchDate : 2024-09-07T15:37:05.474Z
Size : One Size
UnitCount : 1
UnspscCode : 41113700

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.