Specification BatteriesIncluded : 1 BatteriesRequired : 1 Brand : GLTL BulletPoint1 : ●,According to the latest national power industry standards and the design of intelligent voltage test equipment IEC60335J JG795-2015, JJG690-2003. series voltage withstand test instruments are for general- purpose HV test operation. BulletPoint10 : 6 voltage levels---Digital insulation resistance meter consists of medium and large scale integrated circuits. The output power of the watch is large, and the output voltage level is a lot (with 6 voltage levels). DC voltage measurement range is 0 ~ 1000V, AC voltage measurement range is 0 ~ 750V. DC current measurement range is 100pA-6mA. Capacitance measurement range is 10nF-50nF. BulletPoint2 : ●,Third party metrology report can be provided but additional charge is required, please contact us. BulletPoint3 : ●,Widely used in electronic components, electrical manufacturing departments, power operation departments, scientific research units and institutions of higher learning and other industry departments. BulletPoint4 : ●,It has the function of detecting insulation resistance. BulletPoint5 : Can measure AC voltage below 500V (full scale linear indication). BulletPoint6 : Overflow Display---Exceed measurement range overflow function: “> ” symbol display Alarm Function:Alarm when the measured value larger or smaller than the alarm setting value Power Consumption:Standby: 30mA Max(backlight off), Turn on backlight: 42mA Max Measure:200mA Max(backlight off) BulletPoint7 : Weight---Instrument weight:2750g(including battery) Battery voltage:When the battery voltage is low, low battery symbol “ ”will display Automatic shut-down:automatic shutdown after 15 minutes boot Insulation Resistance:≥50MΩ(between Measuring line and housing) Pressure Resistance:AC3kV/50Hz 1min BulletPoint8 : Working environment--Working Temperature and Humidity:-10℃~+50℃<85%RH Storage Temperature and Humidity:-15℃~+55℃<90%RH Suitable for Safety Regulations:IEC61010-1、IEC1010-2-31、IEC61557-1,5、IEC60529(IP54)、pollution grade 2、CAT Ⅲ 300V BulletPoint9 : Application---Digital insulation resistance meter also known as megohmmeter, high voltage insulation resistance tester, etc., for the insulation resistance test. The instrument has a large LCD screen gray backlight display, data storage, data access, alarm, automatic shutdown and other functions. At the same time, it also has the function of measuring DC voltage, AC voltage, absorption ratio and polarization index of DC voltage. The machine is beautiful and upscale, has a wide range, high resolution, convenient operation, easy to carry, accurate, reliable, stable performance, strong anti-interference ability. Color : Grey ExternallyAssignedProductIdentifier1 : 0789789240431 ExternallyAssignedProductIdentifier2 : 789789240431 IncludedComponents : No ItemName : PH7122 Withstand Hi-Pot Insulation Resistance Tester AC/DC 0-5KV AC20mA DC10mA 100VA (110V Input Power) ItemPackageDimensions_Height : 8 centimeters ItemPackageDimensions_Length : 21.5 centimeters ItemPackageDimensions_Width : 16.5 centimeters ItemTypeKeyword : insulation-resistance-meters Manufacturer : GLTL Material : plastic MeasurementAccuracy : 0.1mm ModelName : ANKROYUz89dqutigc ModelNumber : ANKROYUz89dqutigc NumberOfItems : 1 NumberOfLithiumIonCells : 3 PartNumber : PH7122 PowerSourceType : Corded Electric ProductDescription : Test Voltage (AC): 0~5KV +-(2%+/-5V) Test Voltage (DC): 0~5KV +-(2%+/-5V) Leakage Current (AC): 0.1~12mA +/-5% Leakage Current (DC): 0.1~12mA +/-5% Timing (s): 0~99s; Manual control Pmax: 100VA Input Voltage: 220V Insulation resistance test voltage:100~1000V +-(2%+/-5V) 0-100MΩ Weight: 11KG (24lbs)
Pre-used Caution: Read the following items carefully before operating LK7122 series voltage withstand test instrument 1. Use three-hole power supply plug and insure GND connection well. 2. GND port and power supply GND port should be connected well. 3. Wear insulation glove, stand on insulation mat. 4. Before preset all functions, reset instrument. 5. Don’t connect test port and test wire when doing test. 6. Don’t connect HV output port with shield box or GND wire to avoid instrument damage. 7. Operate carefully to avoid hazard when take the remote test. 8.The instrument must be placed on the worktable of conductive materials. 9.The operator can not wear clothes with metal decoration or wear metal accessories. 10.When the tester is in the test conditions, the test line, the test probes, output end , and the test objects are all with high pressure, do not touch!
GLTL is the abbreviated form of General tool. General mean we make products strictly according to ASTM, ISO, UL, IEC, GS, CSN and other industry standards. Tool mean our business scope includes the production and sale of test instruments, measuring tools and professional equipment for applications in manufacturing, electrical appliances, construction and spraying industries.
Among our clients are American Airlines, Germany's Rhine Laboratory (TUV), numerous research institutes and schools. So we provide more favorable price for business customer. ProductSiteLaunchDate : 2019-10-26T07:00:00.000Z Size : Large SpecificationMet : CE Style : VTSYIQI20240520162424VTSYIQI SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnspscCode : 41113600