Teyleten Robot 8 Channel Relay Module with Optocoupler Isolation Support High and Low Level Trigger Expansion Board 5V 1pcs

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 2500/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : Teyleten Robot
BulletPoint : I/Q module E82ZAFSC100
BulletPoint1 : The module adopts high quality relay, normally open interface maximum load: AC 250V/10A, DC 30V/10A;.
BulletPoint2 : The use of chip optocoupler isolation, drive ability, stable performance; trigger current 5mA;
BulletPoint3 : The module can be set through the jumper high level or low level trigger;
BulletPoint4 : Fault-tolerant design, even if the control line is broken, the relay will not act;
BulletPoint5 : Power indicator (green), relay status indicator (red)
BulletPoint6 : Interface design humane, all interfaces can be directly connected through the terminal leads, very convenient
ExternallyAssignedProductIdentifier1 : 0729503061621
ExternallyAssignedProductIdentifier2 : 729503061621
IncludedComponents : NO
ItemName : Teyleten Robot 8 Channel Relay Module with Optocoupler Isolation Support High and Low Level Trigger Expansion Board 5V 1pcs
ItemPackageDimensions_Height : 1.5 centimeters
ItemPackageDimensions_Length : 10 centimeters
ItemPackageDimensions_Width : 8 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : io-modules
Manufacturer : Teyleten Robot
ModelNumber : LR5-02KTNW
NumberOfItems : 1
PackageLevel : unit
PartNumber : WZGS_HDN16617
ProductDescription : Two module interface. 1、DC+:Connect the positive pole of the power supply (voltage according to the requirements of the relay) 2、DC-: connected to the negative pole of the power supply 3, IN: can be high or low level control relay suction Relay output: 1、NO:Normally open relay interface, the relay is suspended before the relay is engaged, after the relay is engaged, it is shorted to COM. 2、COM:relay common interface 3、NC:Normally closed relay interface, shorted to COM before the relay is engaged, suspended after the relay is engaged. High and low level trigger selection terminal: 1. Low level trigger when jumper is shorted to LOW. 2. High level trigger when jumper is shorted to HIGH.
ProductSiteLaunchDate : 2025-04-14T12:31:53.897Z
Style : Modern
SupplierDeclaredDgHzRegulation : not_applicable
SupplierDeclaredHasProductIdentifierExemption : 1
UnspscCode : 39122300

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.