Specification Brand : Generic BulletPoint : Color: FX5-4AD-ADP BulletPoint1 : 1. The measurement accuracy is up to 0.01%FS+0.002mA. BulletPoint2 : 2. The sampling resistance is only 10 ohms (the voltage drop is only 0.2V at 20mA), which has little impact on the system under test. BulletPoint3 : 3. Differential input, can measure forward and reverse current without changing the hardware, easy to use. BulletPoint4 : 4. Automatic power supply polarity change, no need to consider the polarity of the input power supply, not afraid of wrong wiring. BulletPoint5 : 5. Built-in high-performance power conversion circuit, wide input range (7.5V~36V), not afraid of power supply voltage fluctuations, suitable for harsh industrial control environments. ItemName : Wiring Connecting Terminals - GM1001 0-24m Analog to RS485 high-Precision Current Acquisition Module modbus-RTU Protocol ItemTypeKeyword : io-modules Manufacturer : CHIKIMIKI NumberOfItems : 1 PartNumber : CNCK8C053EB1AFD42D35E7C51F1351EDEECD ProductDescription : Specifications: Main Features: 1. The measurement accuracy is up to 0.01%FS+0.002mA. 2. The sampling resistance is only 10 ohms (the voltage drop is only 0.2V at 20mA), which has little impact on the system under test. 3. Differential input, can measure forward and reverse current without changing the hardware, easy to use. 4. Automatic power supply polarity change, no need to consider the polarity of the input power supply, not afraid of wrong wiring. 5. Built-in high-performance power conversion circuit, wide input range (7.5V~36V), not afraid of power supply voltage fluctuations, suitable for harsh industrial control environments. 6. Built-in high-performance power conversion circuit, high efficiency (above 90%), long-term work without heating. 7. The three parts of power supply input, analog measurement channel and communication interface are fully electrically isolated, which can not only make sure safety, but also make sure measurement stability. 8. The RS-485 circuit adopts ADI's high-performance magnetic coupling isolation scheme, which has strong performance, high stability, and is not afraid of interference. 9. The communication interface and calibration parameters are fully controlled and configured, with a high degree of intelligence, and there is no need to open the casing to operate the DIP switch. 10. Standard modbus-rtu protocol, which can be connected with standard equipment such as PLC and HMI. 11. Standard special measurement and control software, powerful and easy to use. ProductSiteLaunchDate : 2024-11-10T09:59:07.051Z UnspscCode : 39121400