SpecificationBatteriesRequired : 1
Brand : XKH
BulletPoint1 :
BulletPoint2 :
BulletPoint3 :
BulletPoint4 :
BulletPoint5 :
BulletPoint6 : ALLOY SHELL: Alloy shell is not easy to rust or corrode, which also has good thermal conductivity and long service life.
Color : White
ExternallyAssignedProductIdentifier : 9186544033474
ExternallyAssignedProductIdentifier1 : 0708176826942
ExternallyAssignedProductIdentifier2 : 708176826942
ItemName : XKH- 120v/240v 8 Light Controller with Trigger Cord/Plant Grow Light Controller (8-Outlet) [P/N: ET-TOOL036-WHITE]
ItemPackageDimensions_Height : 15.3924 centimeters
ItemPackageDimensions_Length : 7.8994 centimeters
ItemPackageDimensions_Width : 13.1064 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : automatic-lawn-irrigation-controllers
Manufacturer : XKH MOTOR
Material : Metal,Steel
ModelName : DI-WT21M-USGN-A302
ModelNumber : DI-WT21M
NumberOfItems : 1
NumberOfPieces : 1
PartNumber : XKH-ET-TOOL036-WHITE
ProductDescription :
SPECIFICATIONS:
- Main Power Voltage: 120V OR 240V
- Receptacle Type: 8 Universal Outlets
- 120V Max Wattage: 4000W total
- 240V Max Wattage: 8000W total/1000W per Outlet
- Max Amperage: 50A
- Trigger Cable Voltage: 120V
- Operating Temperature Range: 32-110°F
- Operating Humidity Range: 0-99% RH Noncondensing
- Minimum Relay Operations: 100,000 @ Full Load
Important Precautions :
- DO NOT install the Light Controller if you are unfamiliar with electrical wiring and circuits OR if you do not fully understand the instructions.
- All local and national electrical codes MUST be followed.
- DO NOT exceed the maximum ratings of this unit.
- Verify all devices to be controlled by the Light Controller are of the correct voltage.
- The unit is for indoor use only. Exercise extreme caution in moist or humid environments.
Main Power Requirements :
- The main power source must be supplied for the lights to function.
- 8 Outlets Light Controller, Use only a 50A, 2-pole circuit breaker and #6 AWG wire to provide the main power.
- Proper connection of the ground wire to the ground lug is critical for safe operation.
- The Light Controller with universal 120/240V receptacles can be used to operate 120V devices ONLY IF the main power is also wired in at 120V.
Installation Notice:
- DO NOT connect ballasts to the Light Controller until AFTER the main power has been properly installed.
- Verify trigger cable is disconnected from the external timer or controller.
- Connect ballast power cables to the receptacles on the Light Controller.
- Connect the trigger cable to the external timer or controller.
ProductSiteLaunchDate : 2021-06-10T19:35:01.306Z
Size : 2 Zone
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
UnspscCode : 39112000
WarrantyDescription : Money Refund or Send Replacement