Specification Brand : PXRZXBICQ BulletPoint1 : [FLEXIBLE SPEED CONTROL] Supports stop, forward, and reverse functions for enhanced usability BulletPoint2 : [HIGH-QUALITY PERFORMANCE] Made of top-notch electronic components for stability and reliability BulletPoint3 : [WIDE VOLTAGE RANGE] Supports DC 12-60V input voltage and up to 10A current BulletPoint4 : [COMPACT DESIGN] Easy installation in tight spaces for convenience BulletPoint5 : [SIMPLE CONTROL] Easily adjust motor rotation using the intuitive knob Color : One Color ExternallyAssignedProductIdentifier : 7320503186104 IncludedComponents : No ItemName : Generator Controller unit 501K auto start control pannel DSE501K Diesel brushless electronic board genset part replace ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : motor-speed-controllers Manufacturer : PXRZXBICQ ModelName : PXRZXBICQ ModelNumber : PXRZXBICQ NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : PXRZXBICQ ProductDescription : Gdianxiaobao_1enerator Controller 501K,The Model 501K-1 is a Manual Engine Control Module,Key Start Module: 501K, 701... Control Modules are provided as follows: 1) Key Start Module: 501K, 701, 702; 2) Auto Start Module: 5110, 5210; 3) Auto/ AMF Start Module: 5120, 5220, 704 The Model 501K-1 is a Manual Engine Control Module, which has been designed to manually control the engine via a key switch on The front panel. The module is used to start and stop the engine, indicating fault conditions; automatically shutting down the engine and indicating the engine failure by LED giving true first up fault annunciation. Operation of the module is via a three position key switch mounted on the front panel with STOP(O), RUN(I) and START(II) positions. In the 'O' position the DC supply is removed from the module and the run relay and alarm output are de-energised. If the switch is turned to the 'I' position the module is powered up and the run relay is energised, activating the engine fuel/ignition system and the protection hold-off timer is initiated. If the switch is moved to the 'II' position and held against the spring , a positive supply is applied to the relevant output terminal and on to the starter motor. Once the engine has started the switch should be released and allowed to to the 'I' position. Operation of any of the following alarms; Low Oil Pressure, High Engine Temperature, Auxiliary Shutdown, Overspeed (Optional), will cause the run relay to de-energise.This will remove the fuel/ignition supply from he engine and bring it to rest. The alarm output will be activated giving a positive DC output. Each alarm channel has it's own LED indicator and once activated no further alarm conditions will be accepted. The alarm output and relevant LED will remain active until the unit is reset by turning the switch to the 'O' position. Overspeed Protection (Op ProductSiteLaunchDate : 2024-11-12T07:46:22.867Z Size : One Size UnitCount : 1 UnspscCode : 26000000 WarrantyDescription : No warranty.