Specification Brand : JZGDX BulletPoint : Oscilloscope Probes BulletPoint1 : Oscilloscope Probes BulletPoint2 : Power source type: Ac BulletPoint3 : Item weight: 0.11 pounds Color : 3CT 400A ExternallyAssignedProductIdentifier : 9495569320453 ItemName : EM-06 Digital Multimeter, Three Phase Volt(L-L),(L-N), Ampere,Frequency, Phase Sequence Display Panel Meter 12 in 1 (Color : 3CT 400A) ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 3 centimeters ItemPackageDimensions_Width : 2 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : oscilloscope-accessories Manufacturer : JZGDX MeasurementAccuracy : 1 ModelName : JZGDX ModelNumber : JZGDX NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : JZGDX PowerSourceType : Ac ProductDescription : Oscilloscope Probes General EM-06 Multimeter are designed to display 3 phase current, voltage and frequency. Usage and Working Principle Make the connections according to the diagram. Connect the current transformers before electric charges to be connected to the system. Current transformers dont sense voltages which connected before them. Apply max 5 A the current inputs. Press the menu button once the energy given to the device.Please enter the current value that you are using by pressing up down buttons, to save it please press menu button once again. If the current transformer value is over 1000/5 please be sure that you can see the kA leds. Under normal working circumstances when the current value is over 1000A KA led that belongs to that phase gets on. You can observe the current values at the sytstem trough the second display group at the right side of the screen. You can see the frequency between phase and phase, phase and neutral at the first display group. When the voltage values is shown (V) led gets on. While pressing the up button ,phase-phase range can be seen.When the phase-phase values is shown you can see the leds on phase phase. While pressing theup buttons you can see the frequency value and Hz led gets on. Phase Sequence: If the phase sequence is reverse you can see the (X) led gets on which take place in the 1st display group. Maintenance Switch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemical might damage the device. Make sure device works after cleaning. Warnings Please use the device according to the manual. Don't use the device in wet. Include a switch and circuit breaker in the assembly. Put the switch and circuit breaker nearby the device, operator can easily. Mark the switch and circuit breaker as releasing connection for device. Specifications Operating Voltage(Un).......: 85V - 240V A ProductSiteLaunchDate : 2024-03-09T03:43:55.028Z Size : One Size UnitCount : 1