Specification Brand : Kavolet BulletPoint1 : [Accurate Measurement] : Bipolar width design, complying with standard din43880 for precise energy reading. BulletPoint10 : Digital power quality logger Operation Method The instrument must be set up before using. Please refer to this manual for setting content. The following precautions for using must be complied with: Do not measure to earth voltage exceeding 600V RMS. Before installing or removing the rechargeable battery, ensure that the instrument is not connected to any test wires and shut down. BulletPoint2 : [Easy Installation] : 35Mm din standard rail mounted for convenient setup according to standards din en 50022. BulletPoint3 : [Energy Efficiency] : Equipped with a polarity passive energy impulse output terminal following standards iec 62053-31 and din 43864. BulletPoint4 : [Impulse Register] : Can select the step motor impulse register of 5+1 digits (99999.1kwh) for detailed tracking. BulletPoint5 : [Standard Compliance] : Measures active energy consumption in on single phase two wire, complying with standards iec 62053-21. BulletPoint6 : Power Quality Analyser also named: Intelligent Three Phase Power Quality Analzer, Multifunctional Power Quality Analyzer and so on, which simultaneous with the functions of harmonic analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. BulletPoint7 : Digital power quality analyzer Test Steps Power up the instrument. Set the voltage¤t ratio, select current sensor and the wiring connection type of power network. Connect the leads and current sensors to the instrument. Connect the neutral line of the current sensor to the neutral line of the tested circuit. Connect the voltage teste line of phase L1 to the phase L1 of power network, and the current sensor of phase L1 clamp on L1 line. BulletPoint8 : Digital power quality meter Measurement Function AC Voltage value between equipment(Max up to 600V) AC current value(Max up to 1000A) Continue voltage, current value 50Hz or 60Hz power network Voltage & current multiple harmonics and total harmonics ratio(not include neutral line) Active power,reactive power(capacitive and inductive) and apparent power(not include neutral line) of each phase Power factor(PF) The harmonic of voltage and current(reach 51 orders, not include neutral line):harmonic ratio, total harmonic ratio, fundamental wave RMS Temperature monitor: display the instrument internal temperature. Phase measurement between voltage and current BulletPoint9 : Digital power quality monitor Setting Function Set the time and date Power network wiring connection selection(single-phase, three-phase three-wires or four-wires) Voltage measure ratio and clamp current sensor selection (All or partial) data delete 50Hz and 60Hz power network selection Voltage & current unbalance formula selection Color : RED IncludedComponents : No ItemName : 220V Digital 1 Phase 2 Wire 2P Electric Meter KWh Bipolar Width Din Rail Energy Meter ItemPackageDimensions_Height : 5 centimeters ItemPackageDimensions_Length : 12 centimeters ItemPackageDimensions_Width : 9 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : industrial-power-meters Manufacturer : Kavolet MeasurementAccuracy : high accuracy ModelName : Kavoletc8dgvemyiz ModelNumber : Kavoletc8dgvemyiz NumberOfItems : 1 NumberOfLithiumIonCells : 2 PartNumber : Kavoletc8dgvemyiz PowerSourceType : Battery Powered ProductDescription : [Accurate Measurement] : Bipolar width design, complying with standard din43880 for precise energy reading. [Easy Installation] : 35Mm din standard rail mounted for convenient setup according to standards din en 50022. [Energy Efficiency] : Equipped with a polarity passive energy impulse output terminal following standards iec 62053-31 and din 43864. [Impulse Register] : Can select the step motor impulse register of 5+1 digits (99999.1kwh) for detailed tracking. [Standard Compliance] : Measures active energy consumption in on single phase two wire, complying with standards iec 62053-21.
Spec:
Features: 35mm DIN standard rail mounted, conforming to Standards DIN EN 50022 Bipolar width, complying with standard DIN43880. Can select the step motor impulse register of 5+1 digits (99999.1kWh) . Equipped with a polarity passive energy impulse output terminal, conforming to Standards IEC 62053-31 and DIN 43864. Two LEDs to indicate separately the power state and the energy impulse signal Measure the active energy consumption in on single phase two wire, which is not related with the load current direction at all, complying with Standards IEC 62053-21. The short terminal cover is made with the transparent PC, to reduce the installation space and is convenient for centralized installation. Specifications: Model: XTM35S Accuracy: Class 1 Voltage: 220V Current: 20(80)A Insulation performance: AC voltage 4kv for 1 minute,1.2/50us waveform impulse voltage 6kv Size: 10*3.6*6.5cm/3.9*1.4*2.6in Weight: Approx.160g/5.6oz Package included: 1 x DIN-Rail Electric Meter 1 x Manual