Specification BatteriesRequired : 1 Brand : VTSYIQI BulletPoint1 : Power quality analyzer 3 phase power quality analyzer three phase power quality analyzer1.Make comprehensive analysis and diagnosis of three-phase power quality. 2.4 types of current sensors provide options to application on various sites. 3.4-channels current and 3-channels voltage are measured simultaneously. 4.The test accuracy is 0.5 class, the test is stable and the anti-interference ability is strong. 5.Touch colorful screen, simple human-machine operation, and switch with different operation language(Chinese & English). 6.USB communication uploads the recorded test results to the computer for analysis. 7.Equip with large capacity lithium battery. BulletPoint10 : Digital power quality logger Operation Method The instrument must be set up before using. Please refer to this manual for setting content. The following precautions for using must be complied with: Do not measure to earth voltage exceeding 600V RMS. Before installing or removing the rechargeable battery, ensure that the instrument is not connected to any test wires and shut down. BulletPoint2 : Power quality meter 3 phase power quality meterportable power quality meter3-Phase Power Quality Meter 1.Waveforms real-time display (3 channels voltages/4 channels currents). 2.True effective values(TRMS) of voltage and current. 3.Phase diagram display. 4.Each phase harmonics measurement, harmonic up to 50 orders. 5.The bar graph shows the harmonic content rate of each phase current and voltage. 6.Total harmonic distortion (THD). 7.Active/reactive/apparent power value and total value of each phase. BulletPoint3 : Power quality analyser 3 Phase Power Quality analyser 3-Phase Power Quality analyser 8.Voltage & current power trend chart. 9.Three-phase unbalance measurement (voltage and current). 10.Record wave forms and parameters. 11.Screenshot and save. 12.Touch screen operation. 13.Voltage flicker, voltage surge and voltage drop capture. 14.Starting current and surge current monitoring. 15.USB interface communicate with the computer host computer. 16.Setting the wiring connection method and power network type of the instrument. Selecting different clamp current sensor and different voltage test ratio. BulletPoint4 : Power quality monitor 3 Phase Power Quality monitor 3-Phase Power Quality monitor Power Quality Analyzer is a high-precision comprehensive test instrument developed by our company for on-site testing of three-phase power quality. The instrument has the characteristics of intelligence, complete functions, simple human-machine operation, and double language operation interface in Chinese and English. The instrument equip with 5-inch touch color screen, small size, light weight, easy to carry, and the current sensor can optional differnt type. The instrument can simultaneously measure 4 channels currents (ABC three-phase and neutral line current) BulletPoint5 : Power quality recorder 3 Phase Power Quality recorder 3-Phase Power Quality recorder Power Quality Analyzer equip with 5-inch touch color screen displayer, which display with different colors to distinguish the parameters, waveforms, phasor diagrams, and harmonic ratio diagrams of each phase, the users can understand the power network parameter status more efficiently and intuitively.. BulletPoint6 : Power Quality Analyser also named: Intelligent Three Phase Power Quality Analzer, Multifunctional Power Quality Analyzer and so on, which simultaneous with the functions of harmonic analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. BulletPoint7 : Digital power quality analyzer Test Steps Power up the instrument. Set the voltage¤t ratio, select current sensor and the wiring connection type of power network. Connect the leads and current sensors to the instrument. Connect the neutral line of the current sensor to the neutral line of the tested circuit. Connect the voltage teste line of phase L1 to the phase L1 of power network, and the current sensor of phase L1 clamp on L1 line. BulletPoint8 : Digital power quality meter Measurement Function AC Voltage value between equipment(Max up to 600V) AC current value(Max up to 6000A) Continue voltage, current value 50Hz or 60Hz power network Voltage & current multiple harmonics and total harmonics ratio(not include neutral line) Active power,reactive power(capacitive and inductive) and apparent power(not include neutral line) of each phase Power factor(PF) The harmonic of voltage and current(reach 51 orders, not include neutral line):harmonic ratio, total harmonic ratio, fundamental wave RMS Temperature monitor: display the instrument internal temperature. Phase measurement between voltage and current BulletPoint9 : Digital power quality monitor Setting Function Set the time and date Power network wiring connection selection(single-phase, three-phase three-wires or four-wires) Voltage measure ratio and clamp current sensor selection (All or partial) data delete 50Hz and 60Hz power network selection Voltage & current unbalance formula selection Color : RED IncludedComponents : No ItemName : VTSYIQI 3 Phase Power Quality Analyzer Digital Three-Phase Power Quality Meter with 4 PCS Current Clamp Sensor 10.0A~6000A CT Size Ф300mm 3 Channels Voltage 4 Channels Current Voltage Range 2V~600V ItemPackageDimensions_Height : 30 centimeters ItemPackageDimensions_Length : 40 centimeters ItemPackageDimensions_Width : 20 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : industrial-power-meters Manufacturer : VTSYIQI20250113114374125242VTSYIQI Material : plastic MeasurementAccuracy : high accuracy ModelNumber : VTSYIQI20250113114374125242VTSYIQI NumberOfItems : 1 PartNumber : VTSYIQI20250113114374125249VTSYIQI PowerSourceType : Battery Powered ProductDescription : VTSYIQI Mini Power Quality Analyzer Three-Phase Power Quality Logger Power Parameter Harmonic Analyzer with 4 PCS Current Clamp Sensor 10mA~10.0A CT Size 17mmX18mm USB Interface IEC-61326 Standard ProductSiteLaunchDate : 2017-03-23T07:00:00.000Z SkipOffer : 1 Style : VTSYIQI2025011311437412524VTSYIQI SupplierDeclaredDgHzRegulation : not_applicable SupplierDeclaredHasProductIdentifierExemption : 1 UnspscCode : 41113600