SpecificationBrand : Dixon
BulletPoint : Price for Pack of 2 pcs
BulletPoint1 : 2 WAY
BulletPoint2 : CONNECTION SIZE 1/2 INCH
BulletPoint3 : PRESSURE 320 PSIG
BulletPoint4 : REGULATING VALVE
BulletPoint5 : TEMP.ACT.VLV. 115/180 F
ConnectorType : Threaded
ExteriorFinish : Aluminum,Silicone
ExternallyAssignedProductIdentifier1 : 0089109756148
ExternallyAssignedProductIdentifier2 : 089109756148
ItemName : Dixon Valve 2182/25, 2182 Blower Air Relief Valve Male NPT, 25 PSI (Pack of 2 pcs)
ItemPackageDimensions_Height : 42 inches
ItemPackageDimensions_Length : 276 inches
ItemPackageDimensions_Width : 42 inches
ItemPackageQuantity : 2
ItemTypeKeyword : industrial-relief-valves
Manufacturer : Dixon Valve
Material1 : Aluminum
Material2 : Silicone
NationalStockNumber : 4820-00-007-2288
NumberOfItems : 2
PartNumber : 2182/25
ProductDescription :
Applications
- Designed specifically for use on tractor mounted air blowers. The 2181 air relief valves have a temperature compensated pressure relief setting to accommodate the high temperatures and dynamic air produced by the blower. If a system blockage were to occur, the valves are designed to vent to atmosphere once the valve pressure setting is achieved.
Features
- High relieving capacity varies between 800 SCFM and 1700 SCFM depending upon the chosen set pressure.
- Installed cup seal deters tampering
- Anodized aluminum body reduces thread galling
Construction
- Aluminum anodized hard coat
- White food grade silicone poppet and diaphragm
Note
- The popular pressure setting for truck mounted blowers is 20 PSI. Valves are available for other applications with temperature compensated pressure settings of between 3 PSI and 24 PSI. Customer should request set pressure at time of order.
- The 2182 valve will relieve at the ordered set pressure at a temperature of 400°F / 204°C. At room temperature 73°F / 22°C the 2182 valve will relieve approximately 4 PSI higher than the ordered set pressure.
- The product label shows the set relief pressure at the blow operating temperature, plus the relief pressure at 73°F / 22°C (for testing purposes). Depending on the blower type, amount of vibration and operating temperature a difference of observable set pressure may occur.
- Example: 2182-18 is set to relieve at 18 PSI while at operating temperature. This same valve will test at 22 PSI while at room temperature on a test bench. Both set points are listed on the label.
ProductSiteLaunchDate : 2020-10-23T13:05:02.178Z
SpecificationMet : UL
SupplierDeclaredDgHzRegulation : unknown
UnitCount : 2
UnspscCode : 40141600
ValveType : air relief valve