Specification Brand : NXUTKBNK BulletPoint1 : Industrial Power Supply BulletPoint2 : HLG-60H-15 60W waterproof LED power supply for PFC street lights Color : One Color ExternallyAssignedProductIdentifier : 6411587075420 ItemName : NXUTKBNK HLG-60H-15 60W Waterproof LED Power Supply for PFC Street Lights ItemPackageDimensions_Height : 1 centimeters ItemPackageDimensions_Length : 1 centimeters ItemPackageDimensions_Width : 1 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : commercial-street-and-area-lighting Manufacturer : NXUTKBNK ModelNumber : NXUTKBNK NumberOfBoxes : 1 NumberOfItems : 1 PartNumber : NXUTKBNK ProductDescription : Industrial Power Supply HLG-60H-15 60W waterproof LED power supply for PFC street lights Model: HLG-60H-15 Work efficiency: 87.5 Power supply type: switching power supply Full range AC input voltage (up to 305VAC) Built-in active PFC (power factor correction) function, when the load is greater than or equal to 60%, the power factor is >0.9 Efficiency up to 90% Fully enclosed aluminum alloy shell with glue potting With short circuit protection/overcurrent protection/overvoltage protection/overheating protection Class 2 power supply unit, passed LPS (limited power supply) test Constant voltage + constant current working mode DC output range 15V, 0~4.0A Constant current voltage range 9~15V Output voltage accuracy ±2% Ripple and noise 150mVp-p Efficiency 87.5% Input voltage range 90~305VAC/127~431VDC Input surge current cold start, 50A/230V Voltage setting range 37~46V (Type A only, adjusted through VoADJ) Current setting range 0.87~1.45A (Type A only, adjusted through IoADJ) <;0.75mA/240VAC When the over-current protection output current reaches 95% ~ 108% of the set current, the constant current limit will resume. When the over-voltage protection output is 48~58V, the output voltage is turned off and restored after restarting. Overheating protection: shuts off the output voltage at 85℃±10℃ (RTH2) and recovers after restarting Start-up rising hold time: 1000mA, 80mA, 16mA/230VAC at full load; 1500mA, 80mA, 16mA/115VAC at full load Insulation characteristics: between input terminal and output terminal: 3.75KVAC, between input terminal and shell: 2KVAC, between output terminal and shell: 0.5KVAC, Operating temperature -40~+70℃ (see output load derating curve) Vibration resistance 10~500Hz, 5G12 minutes/cycle, XYZ each axis 72 minutes each Mean time between failures ≥ 338,000 hours, MIL-HDBK-217F (25℃) Input wiring UL certified, SJTW, 18AWG×3C (30c ProductSiteLaunchDate : 2025-05-17T06:56:26.456Z Size : HLG-60H-15 UnitCount : 1