Specification AgeRangeDescription : adult BatteriesIncluded : 1 BatteriesRequired : 1 Brand : PROVA BulletPoint : Compatible with RH350 Hygro-Thermometer Psychomotor BulletPoint1 : PROVA 136 Temperature Calibrator (RTD + TC) is a High Accuracy Temperature Calibrator BulletPoint2 : Source and measure 14 types of RTD and resistance: PT100 PT10 PT50 PT200 PT500 PT1000 Cu Ni YSI BulletPoint3 : Source and measure 11 types of thermocouples (TC): K, J, E, T, R, S, N, L, U, B, C BulletPoint4 : 4W, 3W, and 2W connections for RTD simulation and measurement BulletPoint5 : Current calibration of 4 fixed values (100μA, 250μA, 1mA, and 2mA) BulletPoint6 : k type rtd fluke dry well block Temperature temp thermocouple probe calibrator simulator equipment Color : Grey ExternallyAssignedProductIdentifier : 7619655538672 ExternallyAssignedProductIdentifier1 : 0860013784409 ExternallyAssignedProductIdentifier2 : 860013784409 Hazmat1 : UN1993 Hazmat10 : DE_SmallLithiumIonBatteryWithEquipment Hazmat11 : EG_SmallLithiumIonBatteryWithEquipment Hazmat12 : ES_SmallLithiumIonBatteryWithEquipment Hazmat13 : FR_SmallLithiumIonBatteryWithEquipment Hazmat14 : GB_SmallLithiumIonBatteryWithEquipment Hazmat15 : IN_SmallLithiumIonBatteryWithEquipment Hazmat16 : IT_SmallLithiumIonBatteryWithEquipment Hazmat17 : JP_SmallLithiumIonBatteryWithEquipment Hazmat18 : MX_SmallLithiumIonBatteryWithEquipment Hazmat19 : NL_SmallLithiumIonBatteryWithEquipment Hazmat2 : UN3481 Hazmat20 : PL_SmallLithiumIonBatteryWithEquipment Hazmat21 : SA_SmallLithiumIonBatteryWithEquipment Hazmat22 : SE_SmallLithiumIonBatteryWithEquipment Hazmat23 : SG_SmallLithiumIonBatteryWithEquipment Hazmat24 : TR_SmallLithiumIonBatteryWithEquipment Hazmat25 : US_SmallLithiumIonBatteryWithEquipment Hazmat26 : ZA_SmallLithiumIonBatteryWithEquipment Hazmat27 : 9 Hazmat3 : II Hazmat4 : AE_SmallLithiumIonBatteryWithEquipment Hazmat5 : AU_SmallLithiumIonBatteryWithEquipment Hazmat6 : BE_SmallLithiumIonBatteryWithEquipment Hazmat7 : BR_SmallLithiumIonBatteryWithEquipment Hazmat8 : CA_SmallLithiumIonBatteryWithEquipment Hazmat9 : CN_SmallLithiumIonBatteryWithEquipment IncludedComponents : PROVA-136 ItemName : Taiwan Quality PROVA 136 Temperature Calibrator (RTD + TC) High Accuracy Temperature Calibrator High Precision Combination of 14 Types of RTD and 11 Types of thermocouples Calibration ItemPackageDimensions_Height : 16 centimeters ItemPackageDimensions_Length : 21 centimeters ItemPackageDimensions_Width : 11 centimeters ItemPackageQuantity : 1 ItemTypeKeyword : temperature-calibrators LowerTemperatureRating : -15 degrees_celsius Manufacturer : PROVA INSTRUMENTS INC. Material : acrylonitrile_butadiene_styrene MeasurementAccuracy : 0.1% ModelName : KATMEPXZ ModelNumber : EC-PROVA-136 NumberOfBoxes : 1 NumberOfItems : 1 NumberOfLithiumIonCells : 1 NumberOfLithiumMetalCells : 1 PackageLevel : unit PartNumber : EC-PROVA-136 PowerSourceType : Battery Powered ProductDescription : Taiwan Quality PROVA 136 Temperature Calibrator (RTD + TC)High Accuracy Temperature Calibrator High precision combination of 14 types of RTD and 11 types of thermocouples calibration PROVA 136Temperature Calibrator (RTD + TC) 1. High precision and combination of RTD and Thermocouple (TC) calibration 2. Source and measure 14 types of RTD and resistance: PT100, PT10, PT50, PT200, PT500, PT1000, Cu, Ni, YSI 3. Source and measure 11 types of thermocouples (TC): K, J, E, T, R, S, N, L, U, B, C 4. 4W, 3W, and 2W connections for RTD simulation and measurement 5. Current calibration of 4 fixed values (100μA, 250μA, 1mA, and 2mA) 6. ℃ and ℉ selectable 7. Accept wide range of excitation current (0.05mA to 5mA) for RTD simulation 8. Individual cold junction compensation (CJC) for simulation and measurement of thermocouples. CJC can be used to fine tune temperature calibration 9. Easy 0% and 100% setup and operation 10. Easy 25%▲ (up) and 25▼ (down) for temperature calibration 11. Individual memory of 0% and 100% setup for different RTD types and thermocouple types 12. Auto step and auto ramp for easy linear calibration 13. Detection of too low or too high excitation current (LO or HI) from the measurement device 14. Warning of exceeding calibrator driving current (IEX) 15. Memory of last setup when power off 16. Easy numerical keypad for input 17. Dot Matrix LCD with backlight 18. Very low power consumption of 30mA with backlight off 19. 15 minutes smart auto-power-off. 15 minutes timer resets itself when any input changes 20. 2 minutes smart auto-backlight-off. 2 minutes timer resets itself when any input changes ProductSiteLaunchDate : 2024-05-30T08:29:44.088Z Size : One Size SpecificationMet1 : CE SpecificationMet2 : RoHS SpecificationMet3 : ISO 9001 SpecificationMet4 : UL SupplierDeclaredDgHzRegulation : transportation UnitCount : 1 UnspscCode : 24101600 UpperTemperatureRating : 55 degrees_celsius Wattage : 9 watts