NGDOLAOV 3P 100A Intelligent Bidirectional Electric Power Kilowatt-Hour Meter Leakage Over-Voltage Protector Relay Switch Current Limiter(EAEMP3C Transformer)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 30400/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : NGDOLAOV
BulletPoint : Thermal Circuit Breakers
Color : One Color
ExternallyAssignedProductIdentifier : 9000062661882
ItemName : NGDOLAOV 3P 100A Intelligent Bidirectional Electric Power Kilowatt-Hour Meter Leakage Over-Voltage Protector Relay Switch Current Limiter(EAEMP3C Transformer)
ItemPackageDimensions_Height : 1 centimeters
ItemPackageDimensions_Length : 3 centimeters
ItemPackageDimensions_Width : 2 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : thermal-circuit-breakers
Manufacturer : NGDOLAOV
ModelNumber : NGDOLAOV
NumberOfItems : 1
PartNumber : NGDOLAOV
ProductDescription : Thermal Circuit Breakers
Product Specifications
Rated voltage: AC380V; Working voltage: AC80V-400V (single phase); Frequency: 50Hz/60HZ
Function:
1. Overvoltage limit: 120-300V (adjustable) (default: 275V)
2. Undervoltage limit: 80-210V (adjustable) (default: 175V)
3. Overcurrent limit: 1-100A (adjustable) (default: 80A)
4. Undercurrent limit: 1-100A (adjustable) (default: 10A)
5. Leakage current limit: 10-99A (adjustable) (default: 29mA) (for use with transformer)
6. High temperature alarm: 10-85 (adjustable) (default: 85)
7. Display mode: Display mode 1, 2 (Default: Display mode 1)
8. Over-voltage and under-voltage protection recovery time 19999s adjustable, default 20s
9 Over-current protection delay 00009999s adjustable default 5s
10 Over-current protection recovery time 00009999s adjustable default 20s
11. Undervoltage and overvoltage protection delay 19999s adjustable, default 3s
12 Three-phase current unbalance alarm 10100 adjustable (default 20%)
13. Voltage three-phase unbalance alarm: 0-100% adjustable (default 20%)
14. Power failure recovery delay time: 1-9999 seconds adjustable (default 20 seconds)
15. Loss of flow event time threshold: 1-999 seconds adjustable (default 10 seconds)
16. Energy consumption reset: closed by default
17. Restore factory : closed by default
18. Device Sharing
19. Remote Control
20. Voice Control
Note: The transformer must pass through a neutral wire and three live wires at the same time, otherwise the leakage value cannot be measured.
ProductSiteLaunchDate : 2024-09-28T04:20:20.365Z
Size : EAEMP3C Transformer
UnitCount : 1

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.