NGDOLAOV DIN Rail 230V Adjustable overvoltage and undervoltage Protection Device Protector Relay Monitoring Current Limit 40A 60A 80A 100A(L N 230V 100A)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 10700/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : NGDOLAOV
BulletPoint : Thermal Circuit Breakers
Color : One Color
ExternallyAssignedProductIdentifier : 7640058768335
ItemName : NGDOLAOV DIN Rail 230V Adjustable overvoltage and undervoltage Protection Device Protector Relay Monitoring Current Limit 40A 60A 80A 100A(L N 230V 100A)
ItemPackageDimensions_Height : 1 centimeters
ItemPackageDimensions_Length : 3 centimeters
ItemPackageDimensions_Width : 2 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : thermal-circuit-breakers
Manufacturer : NGDOLAOV
ModelNumber : NGDOLAOV
NumberOfItems : 1
PartNumber : NGDOLAOV
ProductDescription : Thermal Circuit Breakers
Function:
1. Overvoltage protection
2. Undervoltage protection
3. Overcurrent protection
4. Automatic recovery
5. Voltage display (voltage measurement)
6. Current display (current measurement)
7. Voltage calibration: voltage +-10% adjustable. A13
8. Restore factory : Press and hold the key for more than 12 seconds
9. Fault inquiry: Press and hold the UP button for more than 12 seconds
Product parameters:
1. Model: TOVPD1-60-EC
2. Power supply: 230VAC 50/60Hz
3. Maximum load power: 1~40A adjustable (default 40A)
1~63A adjustable (default 63A)
4. Overvoltage protection value range: 230V~300~OFF (default 270V)
Overvoltage recovery voltage range: 225V-295V (default 250V)
Overvoltage protection action time: 0.1s~30s (default value 0.5s)
Overvoltage recovery delay time: 1s~500s (default 30s)
5. Undervoltage protection value range: 140V--210V--OFF (default 170V)
Undervoltage recovery voltage range: 145V-215V (default 190V)
Undervoltage protection action time: 0.1s~30s (default 0.5s)
Undervoltage recovery delay time: 1s~500s (default 30s)
6. Overcurrent adjustment range: 1-40A (default 20A)
1-63A (Default: 40A)
Overcurrent action range: 0.1~30 seconds (default 0.5 seconds)
Overcurrent recovery delay time: 1s~500s (default 30s)
7. Power-on delay time: 1s~500s (default 10s)
<; 2 weeks
10. Motor life: 100,000 times
11. Installation: 35mm DIN rail
110V version
2. Power supply: 110VAC 50/60Hz
3. Maximum load power: 1~63A adjustable (default 63A)
4. Overvoltage protection value range: 80V~300~OFF (default 145V)
Overvoltage recovery voltage range: 75V-295V (default 140V)
Overvoltage protection action time: 0.1s~30s (default value 0.5s)
Overvoltage recovery delay time: 1s~500s (default 30s)
5. Undervoltage protection value range: 80V--300V--OFF (default 90V)
Undervoltage recovery voltage range: 85
ProductSiteLaunchDate : 2024-09-11T08:43:19.564Z
Size : L N 230V 100A
UnitCount : 1
UnspscCode : 39121601

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.