Specification Brand : CNYST BulletPoint1 : The large bright LCD makes the reading more comfortable, effective abvoid natural light influence. BulletPoint2 : Simple operation, moderate measuring range, cost-effective BulletPoint3 : Unique positioning structure, high-precision optical path system, effectively ensure the accuracy and repeatability of the measurement value. BulletPoint4 : The instrument can be AC and DC powered, low power consumption configuration, compact and lightweight design, easy to use in the field or laboratory. BulletPoint5 : Low voltage indication function, timely instruction to the user to replace the battery, to ensure that the measured value is accurate and effective. IncludedComponents : see details ItemName : CNYST Portable Turbidimeter Turbidity Meter Analyzer with Standard Turbidity Solution Range 0-200NTU for Turbidity Measurement in Power Plants Waterworks Life Sewage Treatment Plant ItemPackageDimensions_Height : 95 millimeters ItemPackageDimensions_Length : 105 millimeters ItemPackageDimensions_Width : 195 millimeters ItemTypeKeyword : science-lab-turbidity-meters Manufacturer : CNYST MeasurementAccuracy : see details ModelNumber : 02025041509 NumberOfItems : 1 PartNumber : 02025041509 ProductDescription : Formazine Standard Turbidity Solution is included During The Shipping !!! General Description: Portable Turbidity Meter is designed for turbidity measurement in accordance with International Turbidity Measurement Standards ISO7027, and provides measurements in traditional unit of NTU, EBC, ASBC
Applications: The instrument widely apply to the turbidity measurement in power plants, waterworks, life sewage treatment plants, drink factories, process water, brewage and drug manufactures departments, hospitals and so on. Note: 1 EBC = 4 NTU (EBC European Brewing Industry Turbidity Unit) 1 ASBC = 0.058 NTU (ASBC American Brewing Industry Turbidity Unit)
Characteristics: The large bright LCD makes the reading more comfortable, effective abvoid natural light influence. The succinct operation, broad measuring range and high cost performance ratio , can suit to various professional applications. The unique localization structure and high accuracy optical path system effectively the measuring value correctness and repeatability In order to avoid affecting the light pass rate, do not touch the optical components in the machine straightly. When maintenance, use absorbent cotton dip in with the mixture of alcohol and aether to clean the surface.
Technical Parameter: Measuring principle: 90° scattered light Measurement range: 0-200 NTU Minimum indication: 0.1 NTU Zero drift: ±1.5%(F.S 30min) Indicative stability: ±1.5%(F.S 30min) Repeatability (Linear Error): ≤2% Indicative error (basic error): ±6% Power supply: No.5 Battery x4 Pcs / 6V power adapter (batterries are not included during the shipment) Net weight:0.4kg Host size:105*195*95mm Storage Requirement:Temperature 0-45℃, humidity<85%.