Brand : Stock Wire
BulletPoint1 : #10 AWG Wire with 3 Annealed (soft) Bare Copper (CU) Conductors
BulletPoint2 : For Indoors for Wet or Corrosive Locations
BulletPoint3 : Use Outdoors for Direct Burial
BulletPoint4 : Has a Heat Capacity of 90 DegreesC and is Rated for 600-Volts, Has an Allowable Ampacity of 30 Amps
BulletPoint5 : Color of Wire May not be the Same as the Picture Shown.
Color1 : Grey
Color2 : Red
Color3 : White
Color4 : Black
ExternallyAssignedProductIdentifier1 : 708744069412
ExternallyAssignedProductIdentifier2 : 0708744069412
ItemName : 10/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (75ft Cut)
ItemPackageDimensions_Height : 4 inches
ItemPackageDimensions_Length : 16 inches
ItemPackageDimensions_Width : 16 inches
ItemPackageQuantity : 1
ItemTypeKeyword : electrical-wires
Manufacturer : Stock Wire
Material : Polyvinyl Chloride
ModelNumber : 222360972578
NumberOfItems : 50
NumberOfWires : 3
PartNumber : 20013
ProductDescription :

Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.

Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH

Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Grey PVC.

Specifications:
Size:10 AWG
Number of Conductors:3
PVC Insulation Thickness:0.024 inches
Ground Wire Size:10 AWG
Nylon Thickness:0.004 inches
Nominal Cable Dimensions:0.727 inches x 0.215 inches
Weight per Foot: 0.102 lbs
Allowable Ampacity: 30 Amps


ProductSiteLaunchDate : 2017-11-22T16:00:00.000Z
Size : 75ft
Strands : 30
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 75
Voltage : 600 volts

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.