14/2 UF-B Copper Wire, Underground Feeder and Direct Earth Burial Cable (50ft)

Imported from USA | Ships in 10 working days

5% instant discount on non COD

1

₹ 8700/-

The price at cart2india.com is inclusive of custom duties, GST, freight forwarding and other charges.

Free Shipping across India. Powered by BlueDart

Product Information


Specification
Brand : Stock Wire
BulletPoint1 : #14 AWG Wire with Annealed (Soft) Copper (Cu) Conductors
BulletPoint2 : Used Indoor for Wet or Corrosive Locations, Resistant to Light and Moisture
BulletPoint3 : Used Outdoor for Direct Earth Burial, Resistant to Sunlight and Moisture
BulletPoint4 : Has a Heat Capacity of 90 Degrees Celcius and is Rated for 600-Volts, Has an Allowable Ampacity of 15 Amps
BulletPoint5 : Color of Wire May not be the Same as the Picture Shown.
Color : Gray
ExternallyAssignedProductIdentifier1 : 680226296397
ExternallyAssignedProductIdentifier2 : 0680226296397
ItemDisplayWeight : 3.25 pounds
ItemName : 14/2 UF-B Copper Wire, Underground Feeder and Direct Earth Burial Cable (50ft)
ItemPackageDimensions_Height : 2 inches
ItemPackageDimensions_Length : 9 inches
ItemPackageDimensions_Width : 9 inches
ItemPackageQuantity : 1
ItemTypeKeyword : electrical-wires
Manufacturer : Stock Wire
Material : Copper
ModelNumber : 250068
NumberOfWires : 3
PartNumber : 250068
ProductDescription :

Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.

Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH

Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Sunlight and moisture resistant gray PVC.

Specifications:
Size:14 AWG
Number of Conductors:2
PVC Insulation Thickness:0.030 inches
Ground Wire Size:14 AWG
Nylon Thickness:0.004 inches
Nominal Cable Dimensions:0.423 inches x 0.168 inches
Weight per Foot: 0.070 lbs
Allowable Ampacity: 15 Amps


ProductSiteLaunchDate : 2018-10-17T11:00:00.000Z
Size : 50ft
Strands : Multi Strand
UnitCount : 1
UnspscCode : 39121400
Voltage : 600 volts

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.