SpecificationBrand : Ancor
BulletPoint1 : Tinned Lug 90degree 1 AWG 3/8", 2pc
BulletPoint2 : 101 degree bend for ease of wire routing and seamless barrel design allows for maximum strength when crimped
BulletPoint3 : Screw size: 3/8", 9.5 mm
BulletPoint4 : Ancor Marine Grade lugs are manufactured from heavy-duty annealed tinned copper, providing for maximum current flow
BulletPoint5 : 100% tin plated copper resists corrosion from salt and moisture
Color : Silver
ConnectorType : Crimp
ExternallyAssignedProductIdentifier1 : 091887991772
ExternallyAssignedProductIdentifier2 : 0091887991772
ExternallyAssignedProductIdentifier3 : 00032886845673
FinishType : Polished
GpsrSafetyAttestation : 1
IncludedComponents : 2 copper lugs
ItemDisplayDimensions_Length : 2.75 inches
ItemDisplayWeight : 2.59 pounds
ItemForm : Coil
ItemName : Ancor 262276 Tinned Lug 90degree #1 3/8", 2pc,Silver
ItemPackageDimensions_Height : 29.6 centimeters
ItemPackageDimensions_Length : 2.5 centimeters
ItemPackageDimensions_Width : 20.5 centimeters
ItemPackageQuantity : 1
ItemShape : Round
ItemTypeKeyword : electrical-wires
Manufacturer : Ancor
Material : Copper
MaximumVoltage : 600 volts_of_direct_current
ModelNumber : 262276
NumberOfItems : 1
NumberOfWires : 2
PackageLevel : unit
PartNumber : 262276
ProductDescription :
Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.
Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH
Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Gray PVC.
Specifications:
Size:10 AWG
Number of Conductors:2
PVC Insulation Thickness:0.024 inches
Ground Wire Size:10 AWG
Nylon Thickness:0.004 inches
Nominal Cable Dimensions:0.518 inches x 0.215 inches
Weight per Foot: 0.178 lbs
Allowable Ampacity: 33 Amps
ProductSiteLaunchDate : 2020-09-09T16:52:01.864Z
Size : 2 Pack
SpecificationMet : UL
Strands : 1
SupplierDeclaredDgHzRegulation : not_applicable
TemperatureRating : 257 degree fahrenheit
TerminalType : Screw Terminal
UnitCount : 1
UnspscCode : 39121400
Voltage : 600 volts