Specification
Brand : wirenco
BulletPoint1 : Color of Wire May not be the Same as the Picture Shown.
BulletPoint2 : Has a Heat Capacity of 90 Degrees Celcius and is Rated for 600-Volts, Has an Allowable Ampacity of 15 Amps
BulletPoint3 : Used Outdoor for Direct Earth Burial
BulletPoint4 : Used Indoor for Wet or Corrosive Locations
BulletPoint5 : #14 AWG Wire with Annealed (Soft) Copper (Cu) Conductors
Color : Gray
ExternallyAssignedProductIdentifier : 30051128544540
ExternallyAssignedProductIdentifier1 : 810080257443
ExternallyAssignedProductIdentifier2 : 0810080257443
IncludedComponents : Cable
ItemName : Wirenco 14/2 UF-B Wire Underground Feeder and Direct Earth Burial Cable (50Ft Cut)
ItemPackageDimensions_Height : 8.1026 centimeters
ItemPackageDimensions_Length : 4.191 centimeters
ItemPackageDimensions_Width : 7.5946 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : electrical-wires
Manufacturer : wirenco
Material : Copper
Material1 : Vinyl
Material2 : Aluminum
Material3 : Copper
ModelNumber : 14/2-UF-W
NumberOfItems : 1
NumberOfWires : 2
PartNumber : 14/2-UF-W
ProductDescription :

Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.

Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH

Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:

Specifications:
Size:14 AWG
Number of Conductors:2
PVC Insulation Thickness:0.030 inches
Ground Wire Size:14 AWG
Nylon Thickness:0.004 inches
Nominal Cable Dimensions:0.423 inches x 0.168 inches
Weight per Foot: 0.070 lbs
Allowable Ampacity: 15 Amps


ProductSiteLaunchDate : 2021-09-21T07:00:00.000Z
Size : 50Ft Cut
Strands : Multi Strand
Style : Pack Of 1
SupplierDeclaredDgHzRegulation : not_applicable
SupplierDeclaredHasProductIdentifierExemption : 1
TemperatureRating : -49°F to 194°F (−45° 90°C)
TerminalType : Screw Terminal
UnitCount : 1
UnspscCode : 26121600
Voltage : 600 volts