Specification
Brand : wirenco
BulletPoint1 : #8 AWG Wire with Annealed (Soft) Copper (Cu) Conductors
BulletPoint2 : Used Indoor for Wet or Corrosive Locations
BulletPoint3 : Used Outdoor for Direct Earth Burial
BulletPoint4 : Has a Heat Capacity of 90 Degrees Celcius and is Rated for 600-Volts, Has an Allowable Ampacity of 40 Amps
BulletPoint5 : Color of Wire May not be the Same as the Picture Shown.
Color : Gray
ExternallyAssignedProductIdentifier1 : 850026183405
ExternallyAssignedProductIdentifier2 : 0850026183405
IncludedComponents : Wire
ItemName : Wirenco 8/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (125Ft Cut)
ItemPackageDimensions_Height : 14.224 centimeters
ItemPackageDimensions_Length : 8.636 centimeters
ItemPackageDimensions_Width : 11.176 centimeters
ItemPackageQuantity : 1
ItemTypeKeyword : electrical-wires
Manufacturer : wirenco
Material : Copper
ModelNumber : 37118-#
NumberOfItems : 1
NumberOfWires : 2
PartNumber : 37118-#
ProductDescription :

Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.

Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH

Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Gray PVC.

Specifications:
Size:8 AWG
Number of Conductors:2
PVC Insulation Thickness:0.035 inches
Ground Wire Size:10 AWG
Nylon Thickness:0.005 inches
Nominal Cable Dimensions:0.678 inches x 0.302 inches
Weight per Foot: 0.222 lbs
Allowable Ampacity: 40 Amps


ProductSiteLaunchDate : 2020-12-29T16:00:00.000Z
Size : 125Ft Cut
Strands : 19
StreetDate : 2017-10-02T00:00:01Z
SupplierDeclaredDgHzRegulation : not_applicable
UnitCount : 1
UnspscCode : 39121400
Voltage : 600 volts

Questions & Answers

Have a question? Ask experts

?
No question found

Ratings & Review

Rating Breakdown (average)

5*
0
4*
0
3*
0
2*
0
1*
0

No reviews found.

Have an opinion on this page? Let's hear it.